Skydio MegaDock
technical specs

MegaDock
Launch TimeAirborne in 20 seconds
Launch / Land WindsUp to 12 m/s (27 mph)
Operational Temperature-20° to 55°C / -4° to 131° F
Dock Dimensions (with fence)14.5’ L x 20.75’ W x 9.5’ H
Deployment Standoff from Buildings10’ on all sides, required for HVAC operation, cargo door access, and maintenance
Total Weight6900 lbs (Total)
6000 lbs (Container)
900 lbs (Fence)
Level Requirement+/- 3°, uniformly sloped
Input/Output1x PoE
Power Input200 - 240 V AC, 60 Hz
Power Load18.033 kW at peak
100A dedicated breaker
Power ConnectionHardwired
Network Requirement[Drones, Minimum, Recommend]
1, 30 mbps, 130 mbps,
3, 75 mbps, 250 mbps
5, 125 mpbs, 400 mbps
Network ConnectionCat6 Ethernet Cable
Onboard Storage1 TB
Unanchored Wind Rating80 mph
Anchored Wind Rating110 mph (Up to 160 mph with partial fence disassembly)
Operational Temperature-20° to 55°C / -4° to 131°F
Standby/Storage Temperature-20° to 60°C / -4° to 140°F
Rain and snow limitationsF10 Operational Capability
0.75”/hr
Dock standby: 4”/hr
Ingress Protection (Operations)IP54
Ingress Protection (Standby)IP56
Corrosion ResistanceDesigned to operate in humid environments, outside of direct saltwater splash zone.
Service Life5 years
Service FrequencyAnnual

What team would you like to contact today?

Support